Drying calculator
Once the weight no longer changes on two days in a row, the seed stands in equilibrium with the air around it. That air's humidity and temperature then give its moisture content, and from that the weight it still has to lose to reach a target.
What was measured
Starting point
Where it should end up
The target range for hemp is 5 % to 7 %. In two storage trials, seed at 5 % or 6 % moisture content kept its germination at least as well as moister seed. The range applies to fridge and freezer alike, and for the freezer the evidence leans against the lower end. Below 4 %, drying can do harm in some species.
All target levels
The row for the selected target moisture is highlighted.
| Target moisture | Gross | Net | Still to lose |
|---|
Where do I stand now
The moisture content is calculated from an estimating equation with an oil content of 32 %, not measured. Measured hemp isotherms range from about 20 % to 94 % humidity. In the dry range the calculation is close to the measurements, at 94 % almost three percentage points too high. The target weight is as accurate as the starting moisture content and the balance.